Skip to main content

elumo Hub - Technical Specifications

J
Written by James Shannon
Updated over a week ago

The elumo Hub provides power and connectivity to the elumo Reader and electric lock as well as acting as the real-time gateway to the elumo platform.

Connectivity

  • Ethernet (RJ45, not supplied)

    • PoE+ 802.3at

    • CAT5 or higher cable (<100m)

  • Wet Lock Relay (3-way screwed Phoenix connector, supplied)

    • Ground

    • Normally Closed (NC)

    • Normally Open (NO)

      Note: 1.2A max @ 12V DC

  • Door Monitor, REX and Reader (8-way screwed Phoenix connector, supplied)

    1. Monitor: Ground

    2. Monitor: V+ (12VDC tolerant, Internal Pullup, Current Limited, Level shifted, Active Low)

    3. REX: Ground

    4. REX: V+ (12VDC tolerant, Internal Pullup, Current Limited, Level shifted, Active Low)

    5. Reader: Ground

    6. Reader: Data 0

    7. Reader: Data 1

    8. Reader: 12VDC+

  • 12V DC input (2-way screwed Phoenix connector, supplied) – advanced installations only

    • 12VDC+

    • Ground

  • Dry Lock Relay (3-way screwed Phoenix connector, not supplied) – advanced installations only

    • Normally Closed (NC)

    • Common

    • Normally Open (NO)

      Note: 2A max @ 30V DC

  • External Relay Board(s) (10-way IDC connector, not supplied) – advanced installations only

Dimensions

Quick Start Guide

Did this answer your question?