The elumo Hub provides power and connectivity to the elumo Reader and electric lock as well as acting as the real-time gateway to the elumo platform.
Connectivity
Ethernet (RJ45, not supplied)
PoE+ 802.3at
CAT5 or higher cable (<100m)
Wet Lock Relay (3-way screwed Phoenix connector, supplied)
Ground
Normally Closed (NC)
Normally Open (NO)
Note: 1.2A max @ 12V DC
Door Monitor, REX and Reader (8-way screwed Phoenix connector, supplied)
Monitor: Ground
Monitor: V+ (12VDC tolerant, Internal Pullup, Current Limited, Level shifted, Active Low)
REX: Ground
REX: V+ (12VDC tolerant, Internal Pullup, Current Limited, Level shifted, Active Low)
Reader: Ground
Reader: Data 0
Reader: Data 1
Reader: 12VDC+
12V DC input (2-way screwed Phoenix connector, supplied) – advanced installations only
12VDC+
Ground
Dry Lock Relay (3-way screwed Phoenix connector, not supplied) – advanced installations only
Normally Closed (NC)
Common
Normally Open (NO)
Note: 2A max @ 30V DC
External Relay Board(s) (10-way IDC connector, not supplied) – advanced installations only
Dimensions